ISO 16890 standard – why is it needed?

Updated 16.11.2026 · Reading time 4 min

In short

ISO 16890 is an international standard for testing and classifying ventilation filters. A filter gets its class based on how large a share of fine particles (PM1, PM2.5 or PM10) it captures. For home supply air, an ePM1 or ePM2.5 class filter is usually suitable – its old designation is F7.

What is ISO 16890?

ISO 16890 is a standard of the International Organization for Standardization (ISO), published in 2016. From 1 July 2018 it replaced the earlier EN 779 standard in Europe, under which filters were designated with letters and numbers (G4, M5, F7, etc.).

The new standard assesses filters closer to real-life use: the whole filter is tested, and it is measured how well it captures fine particles of different sizes. Filter efficiency after the loss of electrostatic charge is also taken into account, which shows how the filter performs over time.

Filter classes: ePM1, ePM2.5, ePM10 and ISO Coarse

A filter gets an ePM class if it captures at least 50% of particles of the corresponding size. The percentage after the class shows efficiency: for example ISO ePM1 70% captures at least 70% of particles up to 1 µm in size.

ePM1
Particles up to 1 µmThe finest particles: traffic and combustion emissions, soot. They reach deep into the lungs.
ePM2.5
Particles up to 2.5 µmFine dust, smoke and combustion particles. The most commonly measured indicator of air pollution.
ePM10
Particles up to 10 µmDust, mould spores and some pollen.
Coarse
Coarse particlesSand, coarse dust, hair and insects. The filter captures less than 50% of PM10 particles.

How do the old designations correspond to ISO 16890 classes?

Many filters, including on our product pages, still use the old designations because buyers are familiar with them. The table below is indicative: the standards test filters differently, so the exact ISO 16890 class depends on the specific filter.

EN 779 (old)ISO ePM1ISO ePM2,5ISO ePM10
G4––generally ISO Coarse
M55–35%10–45%40–70%
M610–40%20–50%60–80%
F740–65%65–75%80–90%
F865–90%75–95%90–95%+
F980–90%85–95%90–95%+

Source: Systemair, “How do filters differentiate in performance”.

Why are fine particles dangerous?

An adult breathes in more than 10,000 litres of air a day. The most dangerous are PM2.5 and PM1 particles, because they reach the pulmonary alveoli and even the bloodstream. Fine particles are linked to asthma, cardiovascular disease and lung cancer.

According to the Council of the European Union, in 2021 97% of Europe’s urban population was exposed to fine particle levels exceeding World Health Organization recommendations. A good ventilation filter is one of the simplest ways to keep indoor air cleaner.

Source: Council of the European Union, “Air pollution in the EU”.

Which filter to choose for your home?

  • Supply air (fresh air into the rooms): an F7, i.e. ePM1 or ePM2.5 class filter. It captures most fine particles.
  • Extract air (air out of the rooms): usually G4 or M5. It protects the unit and heat exchanger from dust.
  • Follow the unit manufacturer’s recommendation. A filter that is too dense restricts airflow and increases energy costs.
  • Replace filters on time, usually every 6 months. A clogged filter doesn’t clean the air well even if its class is high.

Filt.ee filters comply with the ISO 16890 standard and are made in the sizes specified by the unit manufacturer. Each product page shows which filters are included in the set.

Frequently asked questions

What does ISO ePM1 70% mean?

It means that in the ISO 16890 test, the filter captures at least 70% of fine particles up to 1 µm (PM1). The higher the percentage, the better the filter removes fine particles.

Is an F7 filter the same as ePM1?

Not quite. F7 is a designation from the old EN 779 standard, and ISO 16890 tests filters differently. Indicatively, an F7 filter corresponds to ISO ePM1 40–65% or ISO ePM2.5 65–75%. The exact class depends on the specific filter.

Is a higher-class filter always better?

No. A denser filter captures more particles but also restricts airflow more. Use the filter class specified by your ventilation unit’s manufacturer, because a filter that is too dense can reduce airflow and increase energy costs.

Which filter to choose if a family member has allergies?

For supply air, choose the highest ePM1 or ePM2.5 class filter your unit allows, and replace filters on time. In spring, during the pollen season, it’s worth checking the filters more often.

Find the right filters for your unit

Komfovent, Vallox and Flexit – search by your unit model.

Open the filter shopHow often to replace filters?